The sample passes the test if the result is not greater than the volume given in Table ::
S.NO Capacity of container ( corresponding to Volume of 0.01 N HCI per 100 ml of test
90% average overflow volume ) solution (ml )
Type I or II glass Type III Glass
1.Not more than 1 ml 2.00 20.00
2.More than 1ml but not more than 2 ml 1.80 17.60
3. More than 2 ml but not more than 5 ml 1.30 13.20
4. More than 5 ml but not more than 10 ml 1.00 10.20
5. More than 10 ml but not more than 20 ml 0.80 08.10
6. More than 20 ml but not more than 50 ml 0.60 06.10
7. More than 50 ml but not more than 100 ml 0.50 04.80
8. More than 100 ml but not more than 200 ml 0.40 03.80
9. More than 200 ml but not more than 500 ml 0.30 02.90
10. More than 500 ml 0.20 02.20
TRANSLATE IN HINDI ::
अगर रिज़ल्ट टेबल में दिए गए वॉल्यूम से ज़्यादा नहीं है, तो सैंपल टेस्ट पास कर लेता है:
S.NO कंटेनर की कैपेसिटी (टेस्ट के 100 ml प्रति 0.01 N HCI के वॉल्यूम के हिसाब से
90% एवरेज ओवरफ़्लो वॉल्यूम) सॉल्यूशन (ml)
टाइप I या II ग्लास टाइप III ग्लास
1.1 ml से ज़्यादा नहीं 2.00 20.00
2.1ml से ज़्यादा लेकिन 2 ml से ज़्यादा नहीं 1.80 17.60
3. 2 ml से ज़्यादा लेकिन 5 ml से ज़्यादा नहीं 1.30 13.20
4. 5 ml से ज़्यादा लेकिन 10 ml से ज़्यादा नहीं 1.00 10.20
5. 10 ml से ज़्यादा लेकिन 20 ml से ज़्यादा नहीं 0.80 08.10
6. 20 ml से ज़्यादा लेकिन 50 ml से ज़्यादा नहीं 0.60 06.10
7. 50 ml से ज़्यादा लेकिन 50 ml से ज़्यादा नहीं 100 ml 0.50 04.80
8. 100 ml से ज़्यादा लेकिन 200 ml से ज़्यादा नहीं 0.40 03.80
9. 200 ml से ज़्यादा लेकिन 500 ml से ज़्यादा नहीं 0.30 02.90
10. 500 ml से ज़्यादा 0.20 02.20